GENERAL SPECIFICATIONS

Split the cooling solutions for severe conditions.

ISW Water Cooled Type Split units are designed for the areas where there is no infrastructure for cooling solution. Split units consist of two parts as being indoor and outdoor, so these two parts are not affected from environmental conditions of each other’s. Thus the solution is optimized by necessary updates against to harsh environmental conditions such as dust, humidity, corrosive and high ambient temperatures.

TMS_IAC_ISW_Icons-01
ISW

The refrigerants are fully compliant with environmental restrictions. Various compressor and refrigerant type usages brings trouble-free operation with high cooling water temperatures.

Four (4) different indoor units are applicable to be connected to the outdoor units and the quantities of connected units would vary to keep homogenized air balance in the cooled rooms. Each indoor unit brings an advantage depending on your projects as being ceiling type, wall type, duct type or without, slim type, interchangeable wall/ceiling type.

Two (2) fully independent refrigeration circuits are located in one body with their components such as compressor, condenser coils, auxiliary parts, thus it takes less space and keeps the redundancy all the time. Auto switchover function is available as an option and makes equal aging possible with  sequencial operation. Besides, in case one of the circuits fails switches to the other for continuous operation.

Do you have different environmental conditions between indoor and outdoor environment? Don’t you have evaluated infrastructure for your existing areas for cooling systems? Never considered at the beginning? Well, this is the solution for perfect optimizations for your projects.

ISW SPLIT TYPE: INDOOR UNITS

Ceiling Double Suction Type (CDST) Indoor Units

CDST_IAC

Ceiling Single Suction Type (CSST) Indoor Units

IAC-CSST

Ceiling Duct Type (CDT) Indoor Units

IAC_CDT

Ground Duct Type (GDT) Indoor Units

GDT-IAC

ISW SPLIT TYPE: INDOOR UNITS

Ceiling Double Suction Type (CDST) Indoor Units
CDST_IAC
Ceiling Single Suction Type (CSST) Indoor Units
IAC-CSST
Ceiling Duct Type (CDT) Indoor Units
IAC_CDT
Ground Duct Type (GDT) Indoor Units
GDT-IAC

E-ROOM APPLICATION

tr-Electrical-Room-Application-Example2

Electrical Room Application

SEE OUR OTHER IAC SERIES PRODUCTS

ISCW-Water_Cooled_SCU_Type_Product_box
ISCW Water
Cooled SCU Type

Engineered to Operate in
Severe Ambient Conditions

new-IHDO-Product_box
IHDO Heavy Duty
Outdoor Type

Engineered to Perform in
Heavy Industry Conditions

ISA-Product_box
ISA Air Cooled
Split Type

Split Industrial Conditions
for Heavy Industry